Development Length in Rcc

Development Length Calculation as per Indian Code
Development length is the extra length of bar provided beyond the required section in order to ensure the following;
  • To develop a safe bond between the bar surface & the concrete so that no failure due to slippage of bar occurs during the ultimate load conditions.
  • Also, the extra length of the bar provided as development length is responsible for transferring the stresses developed in any section to the adjoining sections (such as at column beam junction the extra length of bars provided from beam to column).
Importance: Provision of appropriate development is an important aspect of safe construction practices, proper development length in reinf. bars shall be provided as per the steel grade considered in design otherwise in scenarios where less development length against the required is provided the structures will be prone to encounter  failure due to slippage of joints, bonds, anchors & Laps, in such cases the bars will not yield first but the failure will happen at joints & laps prior to yielding of reinforcement bars.
Calculation of Development length:As per the Indian Standard – IS 456: 2000, clause 26.2.1 the development length Ld is given the following expression;
 Where,             Ø            = nominal dia of reinforcement bar
 σs= Stress in bar at the section considered at design load τbd           = Design bond stressThe above given formula is used to calculate the required development length in mm for any given dia of bar, same formula is used for limit state method as well as working stress method. The only change in calculation in both methods is due to the different value of design bond stress; the values of design bond for Limit State & working stress are as follows;